Electronic HIPPS

It is a full electronic HIPPS system, with electronic Pressure Transmitter as initiators that upon request may be installed within an Interlock Manifold, so that to prevent disconnection of more than one line instrument. The signals of the PTs are sent to an electronic Logic Solver, which can be solid state or Programmable PLC, which process the signals and give output signal to the final elements to perform fast shutdown usually in the range of 2÷3 seconds.

Electronic HIPPS systems can be provided with elements supplied as loose items, or skid-mounted as a package system ready to be installed on the pipeline.

A HIPPS is a closed functional loop, composed by following elements:

  1. Initiators: they are the elements installed to detect the overpressure in the line, to start the shutdown process. For electronic HIPPS, they are electronic pressure transmitters for electronic HIPPS (in order to guarantee the systems reliability in accordance to SIL 3 requirements, 3 sensors are installed in parallel). For mechanical HIPPS, they are mechanical initiators.
  2. Logic solver (only for electronic HIPPS): it is the element which processes the input signals from the initiators and gives output the activation instruction to the solenoid valves of the final elements to shutdown the line. It could be solid state wired-logic type or programmable PLC.
  3. Final elements: they are the elements which physically perform the fast shutdown of the line once received the signal from the Logic solver or mechanical initiators, achieving the safe condition for downstream plant. They are on-off valves with hydraulic or pneumatic actuators.
Valves designBall side entry / top entry or Slab gate
Pressure ratingAPI 6D: ANSI 150 to 2500
API 6A: API 2,000 to 20,000 psi
Temperature-100°C to + 200°C
Bore sizesAPI 6D: 2” to 48”
API 6A: 1.13/16” to 9
Material optionsCarbon and low alloy steels, stainless steel, duplex and super duplex steels, CRAs
ActuationHydraulic and pneumatic (spring return), self-contained for mechanical HIPPS
Quality certifications and approvalsAPI 6A, API 6D, Fire safe API 6FA, PED 2014/68/UE, ATEX
VALVES SPECIFICATION

Breda Energia can offers 2 different solutions of HIPPS, electronic type or mechanical type.

Related Products